01
Key Parameters
QLY-S 5×1.5+2×4 / 24 V
- Constant operating temperature
- -40 °C to +90 °C (according to ISO 4141)
- Rated voltage
- 24 V
- Maximum conductor temperature during cable operation
- +90 °C
- Max. short-term operating temperature during a short circuit
- +110 °C (max. 5 sec. on the vein)
- Minimum ambient temperature for permanently installed cables
- -40 °C
- Minimum cable installation temperature
- -5 °C
- Test voltage at 50 Hz
- 1,500 V (AC)
- Minimum bending radius for permanent joints
- 5 x Ø
02
Construction
QLY-S 5×1.5+2×4 / 24 V
- A wire made of Class 5 bare electrolytic copper (Cu-ETP1) in accordance with standards
- IEC 60228.
- Insulation
- Heat-resistant PVC insulation; conductors in various colors in accordance with ISO 6722.
- Outer shell
- Thermoplastic polyurethane coating, black.
- Printing on the cable
- as requested by the customer.
For larger outer diameters, the core is wrapped in paper tape or nonwoven fabric.
03
Application
QLY-S 5×1.5+2×4 / 24 V
Used in electrical installations and for connecting motor vehicles to trailers.
04
Technical Tables
QLY-S 5×1.5+2×4 / 24 V
| Number and cross-sectional area of the wire [mm²] | Outer diameter [mm] | Approximate cable weight [kg/km] |
|---|---|---|
| 5 x 1,5 +2 x 4 | 13 ± 0,5 | 255 |
05