Przejdź do głównej treści

MGWIRES

KATALOG PRODUKTÓW Znajdź konkretny kabel
MG WIRES / KARTA KATALOGOWA

H1Z2Z2-K AR

H1Z2Z2-K AR solar cable with halogen-free insulation and sheath for photovoltaic systems.

ZAPYTAJ O OFERTĘ → PL
01

Key parameters

Continuous working temperature
−40 °C to +90 °C
Elevated working temperature
Maximum +120 °C for 20 000 h
DC operating voltage
1.5 kV, maximum 1.8 kV
AC rated voltage
1.0/1.0 kV
Maximum conductor temperature in operation
+90 °C
Short-circuit temperature
+250 °C, maximum 5 s on conductor
Minimum allowable ambient temperature
−40 °C
Minimum installation temperature
−25 °C
Test voltage, 50 Hz
6500 V AC
Minimum bending radius
4 × cable diameter
Expected period of use
25 years
CPR reaction-to-fire class
B2ca according to EN 50575
EN 50618 test certificate
1250124
02

Construction

Conductor
Soft-annealed tin-plated electrolytic copper Cu-ETP1, class 5 according to IEC 60228 and DIN EN 13602
Insulation
Crosslinked special halogen-free compound, white
Outer sheath
Crosslinked special halogen-free compound, black, red or blue
03

Properties

UV and weathering resistance according to EN 50618. Resistance to ammonia. Halogen-free, resistant to acids and alkalis.

04

Standards

PN-EN 50618:2015-03; EN 60332-1; IEC 60332-1; PN-EN 61034-2; PN-EN 60754-2; EN 50575; IEC 60228; DIN EN 13602.

05

Application

Connections between individual solar panels and between panels and the inverter in photovoltaic installations.

06

Technical tables

Dimensions and insulation

Dimensions and insulation
Cross-section [mm²]Maximum diameter of single wire in conductor [mm]Nominal insulation thickness [mm]Nominal jacket thickness [mm]Maximum outside cable diameter [mm]Minimum insulation resistance at 20 °C [MΩ·km]Minimum insulation resistance at 90 °C [MΩ·km]
2,50,260,70,85,96900,86
40,310,70,86,65800,58
60,310,70,87,45000,50
100,410,70,88,84200,42
160,410,70,910,13400,34
250,410,91,012,53400,34

Other cross-sections and constructions are available on request.

Current carrying capacity

Current carrying capacity
Cross-section [mm²]Single cable free in air [A]Single cable on a surface [A]Two loaded cables touching on a surface [A]
2,5413933
4555244
6706757
10989379
16132125107
25176167142
07

Available versions

Black, red or blue outer sheath. Optional galvanized steel wire FeZn reinforcement. Other cross-sections and constructions are available on request.

08

Additional information

Anti-rodent protection

The AR version has an anti-rodent agent in the outer sheath.

09

Dokumentacja