01
Key Parameters
- Operating temperature
- from -40 °C to +105 °C
- Permissible temperature during a short circuit
- +160 °C
- Operating voltage
- 60 V
- Voltage Test
- 1,000 V
02
Construction
- Vein
- made of soft copper or tin-plated copper wires (Cu-ETP1), Class 5 according to PN-EN 60228
- Insulation
- PVC
03
Properties
Good mechanical properties
Resistance to automotive fuels and oils
04
Standards
PN-E-90181:1974
05
Application
Single-conductor cables designed for low-voltage electrical systems in automobiles and other road vehicles.
06
Technical Tables
| Rated conductor cross-sectional area [mm²] | Maximum allowable wire diameter in a strand [mm] | Nominal insulation thickness [mm] | Maximum outer diameter of the cable [mm] | Maximum resistance of the conductor at 20 °C [Ω/km] |
|---|---|---|---|---|
| 0,50 | 0,21 | 0,6 | 2,3 | 39,00 |
| 0,75 | 0,21 | 0,6 | 2,6 | 26,00 |
| 1,00 | 0,21 | 0,6 | 2,7 | 19,50 |
| 1,50 | 0,26 | 0,6 | 3,0 | 13,30 |
| 2,50 | 0,26 | 0,6 | 3,5 | 7,98 |
| 4,00 | 0,31 | 0,6 | 4,0 | 4,95 |
| 6,00 | 0,31 | 0,6 | 5,1 | 3,30 |
| 10,00 | 0,41 | 0,8 | 6,7 | 1,91 |
| 16,00 | 0,41 | 0,8 | 7,8 | 1,21 |
| 25,00 | 0,41 | 1,0 | 9,8 | 0,78 |
| 35,00 | 0,41 | 1,2 | 11,7 | 0,554 |
| 50,00 | 0,41 | 1,4 | 13,7 | 0,386 |
| 70,00 | 0,51 | 1,4 | 15,6 | 0,272 |
| 95,00 | 0,51 | 1,6 | 19,0 | 0,206 |
| 120,00 | 0,51 | 1,6 | 20,3 | 0,161 |
Other cross-sections and designs are available upon request according to the customer's specifications.