Key Parameters

Rated voltage
0.6/1.0 kV
Maximum core temperature during operation
+90 °C
Short-circuit temperature
+250 °C, for a maximum of 5 seconds on the wire
Minimum ambient temperature for permanent installation
−30 °C
Installation temperature
−5 °C to +50 °C
Test voltage, 50 Hz
4,000 V AC
Minimum bending radius
Single-conductor cables: 15 × cable diameter; multi-conductor cables: 12 × cable diameter
02

Construction

Vein
Bare copper Cu-ETP1, Class 1 or 2 according to IEC 60228 and DIN EN 13602
Insulation
Halogen-free cross-linked polyethylene (XLPE), HD 604 S1, Type 2XI1
Multi-conductor cable terminations
Twisted wires with optimal pitch
Filling
Self-extinguishing, halogen-free thermoplastic compound
Coating
Halogen-free HM4 plastic in accordance with HD 604 S1, black
Wire Markings
In accordance with DIN VDE 0293-308; version without a protective conductor
03

Properties

Halogen-free cable with enhanced fire resistance.

04

Standards

DIN VDE 0276-604; HD 604 S1-1+5G; IEC 60228; DIN EN 13602; DIN VDE 0293-308; PN-EN 60332-1; EN 60332-1; IEC 60332-1; PN-EN 60754-2; EN 60754-2; IEC 60754-1; IEC 60754-2; PN-EN 50575.

05

Application

Permanent installations in facilities requiring protection of people and property in the event of a fire, including hotels, hospitals, schools, airports, subways, railways, and industrial facilities. Installation in dry and damp environments: on plaster, under plaster, flush with plaster, in masonry walls, and directly in concrete. Cable ducts or protective conduits are required for outdoor or underground installation.

06

Technical Tables

Dimensions of single-conductor cables

Dimensions of single-conductor cables
Number and cross-sectional area of conductors [mm²]Cable diameter [mm]Cable weight [kg/km]
1 x 1,5 RE5,239
1 x 2,5 RE5,551
1 x 4 RE6,067
1 x 6 RE6,587
1 x 10 RM7,3128
1 x 16 RM8,3194
1 x 25 RM10,2292
1 x 35 RM11,4386

RE — single-strand round conductors; RM — multi-strand round conductors.

Dimensions of Multi-Conductor Cables

Dimensions of Multi-Conductor Cables
Number and cross-sectional area of conductors [mm²]Cable diameter [mm]Cable weight [kg/km]
2 x 1,5 RE8,9119
2 x 2,5 RE9,7150
2 x 4 RE10,6195
2 x 6 RE11,6250
2 x 10 RM13,2360
2 x 16 RM15,5542
3 x 1,5 RE9,3134
3 x 2,5 RE10,1174
3 x 4 RE11,1231
3 x 6 RE12,2302
3 x 10 RM14,2454
3 x 16 RM16,4683
4 x 1,5 RE10,0157
4 x 2,5 RE10,9207
4 x 4 RE12,1278
4 x 6 RE13,3372
4x 10 RM15,5564
4 x 16 RM18,0858
5 x 1,5 RE10,8184
5 x 2,5 RE11,9245
5 x 4 RE13,1333
5 x 6 RE14,7455
5 x 10 RM17,0682
7 x 1,5 RE11,9231
7 x 2,5 RE13,0311
7 x 4 RE14,9447

RE — single-strand round conductors; RM — multi-strand round conductors.

07