MG WIRES / TECHNICAL DATA
REQUEST A QUOTE →
PL
H00V-D
H00V-D single-core cable for grounding and short-circuiting equipment.

01
Key Parameters
- Operating temperature according to standard
- −5 °C to +70 °C
- Minimum bending radius
- 4 × cable diameter
- AC test voltage
- 10–16 kV depending on wall thickness
- DC test voltage
- 15–22 kV depending on wall thickness
02
Construction
- Conductor
- Soft bare copper, class 6 according to EN 60228
- Insulation
- PVC/ST5 polyvinyl chloride
- Insulation color
- Transparent
- Insulation material temperature range
- −25 °C to +70 °C
- Insulation material short-term temperature
- +100 °C
03
Properties
Resistance to thermal shock, UV radiation and aging. Mechanical strength and flexibility. Permanent marking printed under the insulation.
04
Standards
PN-EN 61138:2009; EN 60228, class 6.
05
Technical Tables
H00V-D / H00V3-D
| Nominal core cross-section [mm²] | Largest wire diameter in strand [mm] | Nominal insulation thickness [mm] | Approximate outside cable diameter [mm] | Approximate cable weight [kg/km] |
|---|---|---|---|---|
| 16 | 0,21 | 1,2 | 8,0 ± 0,2 | 196 |
| 25 | 0,21 | 1,2 | 10,0 ± 0,2 | 312 |
| 35 | 0,21 | 1,2 | 11,0 ± 0,2 | 417 |
| 50 | 0,31 | 1,5 | 13,2 ± 0,2 | 610 |
| 70 | 0,31 | 1,8 | 15,8 ± 0,2 | 930 |
| 95 | 0,31 | 1,8 | 18,3 ± 0,2 | 1234 |
| 120 | 0,31 | 1,8 | 19,9 ± 0,2 | 1570 |
06
Available versions
Cable reels or drums.