MG WIRES / TECHNICAL DATA
REQUEST A QUOTE →
FLR11YC11Y
FLR11YC11Y single-conductor shielded automotive cable with polyurethane insulation and jacket. The specifications and table below apply to the 70 mm² version.
01
Key Parameters
- Operating temperature
- −40 °C to +150 °CFLR11YC11Y 70 mm²
- Temperature class
- D according to ISO 6722FLR11YC11Y 70 mm²
- Rated voltage
- 600 VFLR11YC11Y 70 mm²
- Maximum core temperature
- +150 °CFLR11YC11Y 70 mm²
- Minimum temperature for permanent installation
- −40 °CFLR11YC11Y 70 mm²
- Minimum installation temperature
- −5 °CFLR11YC11Y 70 mm²
- Test voltage
- 3,500 V AC, 50 HzFLR11YC11Y 70 mm²
- Minimum bending radius for permanent installation
- 5 × the cable's diameterFLR11YC11Y 70 mm²
- Halogen-free
- IEC 60754-1FLR11YC11Y 70 mm²
02
Construction
Conductor: bare copper Cu-ETP1, Class 5 according to IEC 60228. Insulation: heat-resistant polyurethane with a hardness of 85 ShA, orange RAL2004. Core wrapped in Al-PET tape and a braided CuSn shield with approximately 85% coverage. Outer sheath: heat-resistant thermoplastic polyurethane, 85 ShA, orange RAL2004, marked with the manufacturer’s name, type, cross-section, and lot number.
03
Application
Automotive wiring.
04
Technical Tables
70 mm² version
| Wire cross-sectional area [mm²] | Conductor construction [n × mm] | Rated insulation thickness [mm] | CuSn screen design [(n × mm) × a] | Rated coating thickness [mm] | Outer diameter [mm] | Approximate weight [kg/km] |
|---|---|---|---|---|---|---|
| 70 | 555 × 0,40 | 1,40 | (12 × 0,20) × 24 | 2,10 | 18,70 ± 0,30 | 920 |
Other designs and dimensions are available upon request.
05