MG WIRES / TECHNICAL DATA
REQUEST A QUOTE →
FLYY
Single-conductor, low-voltage automotive cables. FLYY – low-voltage automotive cable (FL), with polyvinyl chloride insulation (Y) and a sheath (Y)
01
Key Parameters
- Operating temperature of cables
- -40 °C to 100 °C
02
Construction
- Vein
- Copper, multi-strand, flexible (per ISO 6722-1)
- Insulation
- PVC, Class B (according to ISO 6722-1)
03
Standards
Standards / Specifications STANDARD: ISO 6722-1; ECE-R 118
04
Technical Tables
| Number of conductors × Nominal cross-sectional area / mm² | Conductor Construction / Number of Wires | Conductor Construction / Single-Wire Diameter / (max.) / mm | Resistance at 20 °C / (max.) / mΩ/m | Insulation wall thickness / (nom.) / mm | Coating thickness / (nom.) / mm | Outer diameter of the cable / (max.) / mm |
|---|---|---|---|---|---|---|
| 0,50 | 16 | 0,21 | 37,1 | 0,6 | 0,4 | 3,1 |
| 0,75 | 24 | 0,21 | 24,7 | 0,6 | 0,4 | 3,3 |
| 1,00 | 32 | 0,21 | 18,5 | 0,6 | 0,4 | 3,6 |
| 1,50 | 30 | 0,26 | 12,7 | 0,6 | 0,5 | 4,1 |
| 2,00 | 40 | 0,26 | 9,42 | 0,6 | 0,5 | 4,3 |
| 2,50 | 50 | 0,26 | 7,61 | 0,7 | 0,5 | 4,8 |