01
Key Parameters
- Constant operating temperature
- -80 °C to +205 °C/3,000 h (ISO 6722 Class F).
- Rated voltage
- 250 V
02
Construction
- Vein
- Class 5 tinned copper wire in accordance with EN/IEC 60228, grade Cu-ETP1
- Insulation
- FEP-type thermoplastic fluoropolymer, available in all solid colors
03
Properties
Excellent resistance to harsh chemical environments.
Excellent resistance to moisture and UV radiation.
Exceptional resistance to fuels, oils, and lubricants.
Excellent mechanical strength.
Self-extinguishing and non-flammable, UL94 – V0.
04
Technical Tables
| Conductor cross-sectional area [mm²] | Approximate nominal conductor diameter [mm] | Nominal insulation thickness [mm] | Min. insulation thickness [mm] | Approximate outer diameter of the cable [mm] |
|---|---|---|---|---|
| 0,35 | 0,80 | 0,25 | 0,20 | 1,20 |
| 0,50 | 0,94 | 0,28 | 0,22 | 1,40 |
| 0,75 | 1,20 | 0,30 | 0,24 | 1,70 |
| 1 | 1,34 | 0,30 | 0,24 | 1,85 |
| 1,5 | 1,60 | 0,30 | 0,24 | 2,10 |
| 2,5 | 2,10 | 0,35 | 0,28 | 2,65 |
| 4 | 2,50 | 0,40 | 0,32 | 3,15 |
| 6 | 3,10 | 0,40 | 0,32 | 3,75 |
Other cross-sections and designs are available upon request.