H1Z2Z2-K US
H1Z2Z2-K US cable for photovoltaic installations, with halogen-free insulation and jacket, and an outer armor made of galvanized steel wires.

Key Parameters
- Operating temperature
- −40 °C to +90 °C
- Elevated operating temperature
- Up to +120 °C for 20,000 hours
- DC Operating Voltage
- 1.5 kV, up to 1.8 kV
- Rated AC voltage
- 1.0/1.0 kV
- Maximum core temperature during operation
- +90 °C
- Short-circuit temperature
- +250 °C, for a maximum of 5 seconds on the wire
- Minimum ambient temperature for permanent installation
- −40 °C
- Minimum installation temperature
- −25 °C
- Test voltage: 50 Hz
- 6,500 V AC
- Minimum bending radius for permanent installation
- 4 × cable diameter
- Expected service life
- 25 years
- CPR Fire Reaction Class
- Dca according to EN 50575
- EN 50618 Certificate
- 1250124
Construction
- Vein
- Tin-plated electrolytic copper Cu-ETP1, Class 5 according to IEC 60228 and DIN EN 13602
- Insulation
- Special halogen-free cross-linked plastic, white
- Coating
- Special halogen-free cross-linked plastic, available in black, red, or blue
- Armament
- Outer braid made of FeZn-galvanized steel wires; minimum braid density of 90%
Properties
Resistant to UV, ozone, hydrolysis, and ammonia. Halogen-free construction with enhanced resistance to acids and bases.
Standards
PN-EN 50618:2015-03; EN 60332-1; IEC 60332-1; PN-EN 61034-2; PN-EN 60754-2; EN 50575; IEC 60228; DIN EN 13602.
Application
Connections between solar panels and between the panels and the inverter. The FeZn external coating enhances resistance to mechanical damage and damage caused by rodents.
Technical Tables
US production
| Wire cross-sectional area [mm²] | Maximum wire diameter in a strand [mm] | Nominal insulation thickness [mm] | Nominal coating thickness [mm] | Approximate diameter of the cable in the conduit [mm] | Minimum insulation resistance at 20 °C [MΩ·km] | Minimum insulation resistance at 90 °C [MΩ·km] |
|---|---|---|---|---|---|---|
| 2,5 | 0,26 | 0,7 | 0,8 | 5,1 | 690 | 0,86 |
| 4 | 0,31 | 0,7 | 0,8 | 6,0 | 580 | 0,58 |
| 6 | 0,31 | 0,7 | 0,8 | 6,7 | 500 | 0,50 |
| 10 | 0,41 | 0,7 | 0,8 | 8,5 | 420 | 0,42 |
| 16 | 0,41 | 0,7 | 0,9 | 9,4 | 340 | 0,34 |
| 25 | 0,41 | 0,9 | 1,0 | 12,0 | 340 | 0,34 |
Other cross-sections and designs are available upon request.
Current-Carrying Capacity
| Wire cross-sectional area [mm²] | A single overhead cable [A] | A single cable on the surface [A] | Two cables side by side on surface [A] |
|---|---|---|---|
| 2,5 | 41 | 39 | 33 |
| 4 | 55 | 52 | 44 |
| 6 | 70 | 67 | 57 |
| 10 | 98 | 93 | 79 |
| 16 | 132 | 125 | 107 |
| 25 | 176 | 167 | 142 |
Available versions