Skip to main content

MGWIRES

PRODUCT CATALOG Find a specific cable
MG WIRES / TECHNICAL DATA

H1Z2Z2-K AR

H1Z2Z2-K AR cable with halogen-free insulation and jacket, for photovoltaic installations. The jacket contains a rodent-repellent additive.

REQUEST A QUOTE → EN
01

Key Parameters

Operating temperature
−40 °C to +90 °C
Elevated operating temperature
Up to +120 °C for 20,000 hours
DC Operating Voltage
1.5 kV, up to 1.8 kV
Rated AC voltage
1.0/1.0 kV
Maximum core temperature during operation
+90 °C
Short-circuit temperature
+250 °C, for a maximum of 5 seconds on the wire
Minimum ambient temperature for permanent installation
−40 °C
Minimum installation temperature
−25 °C
Test voltage: 50 Hz
6,500 V AC
Minimum bending radius for permanent installation
4 × cable diameter
Expected service life
25 years
CPR Fire Reaction Class
B2ca according to EN 50575
EN 50618 Certificate
1250124
02

Construction

Vein
Tin-plated electrolytic copper Cu-ETP1, Class 5 according to IEC 60228 and DIN EN 13602
Insulation
Special halogen-free cross-linked plastic, white
Coating
Special halogen-free cross-linked plastic, black, red, or blue; with rodent-repellent additive
03

Properties

Resistant to UV, ozone, hydrolysis, and ammonia. Halogen-free construction with enhanced resistance to acids and bases.

04

Standards

PN-EN 50618:2015-03; EN 60332-1; IEC 60332-1; PN-EN 61034-2; PN-EN 60754-2; EN 50575; IEC 60228; DIN EN 13602.

05

Application

Connections between solar panels and between the panels and the inverter.

06

Technical Tables

Dimensions and Insulation

Dimensions and Insulation
Wire cross-sectional area [mm²]Maximum wire diameter in a strand [mm]Nominal insulation thickness [mm]Nominal coating thickness [mm]Maximum cable diameter [mm]Minimum insulation resistance at 20 °C [MΩ·km]Minimum insulation resistance at 90 °C [MΩ·km]
2,50,260,70,85,96900,86
40,310,70,86,65800,58
60,310,70,87,45000,50
100,410,70,88,84200,42
160,410,70,910,13400,34
250,410,91,012,53400,34

Other cross-sections and designs are available upon request.

Current-Carrying Capacity

Current-Carrying Capacity
Wire cross-sectional area [mm²]A single overhead cable [A]A single cable on the surface [A]Two cables side by side on surface [A]
2,5413933
4555244
6706757
10989379
16132125107
25176167142
07

Available versions

Black, red, or blue coating. Reinforcement can be made from FeZn-galvanized steel wire. Other cross-sections and designs available upon request.

08

Documentation