Skip to main content

MGWIRES

PRODUCT CATALOG Find a specific cable
MG WIRES / TECHNICAL DATA

MGW FEP/SiR

Wiring of measurement and control devices in professional electronics; hot, cold, and chemically aggressive environments; installations requiring compact dimensions and flexibility.

REQUEST A QUOTE →
01

Key Parameters

MGW FEP/SiR 3×0.22

Continuous operating temperature
−60 °C to +200 °C
Operating voltage
300/500 V
Test voltage
2,500 V
02

Construction

MGW FEP/SiR 3×0.22

Vein
Tinned copper, Class 5 according to DIN VDE 0295 / BS 6360 / HD 383 / IEC 60228
Insulation
FEP
Coating
EI2 Silicone Rubber
Colors
White–white–red insulation; brick-red jacket
03

Technical Tables

MGW FEP/SiR 3×0.22

Technical Specifications — MGW FEP/SiR 3×0.22
Number and cross-sectional area of conductors [mm²]Rated insulation thickness [mm]Diameter of the insulated conductor [mm]Rated coating thickness [mm]Average outer diameter [mm]
3 x 0,220,201,051,254,75 ± 0,07
04

Available versions

Other cross-sections, conductor counts, and jacket colors are available upon request. The 205 °C temperature of the FEP material does not raise the operating temperature of the entire cable above 200 °C.

05