MG WIRES / TECHNICAL DATA
REQUEST A QUOTE →
H07BQ-F
These cables are designed for use wherever there is a high risk of mechanical damage (pulling, dragging, sliding, bending), in dry, damp, and wet environments as well as in open areas; they are used to connect industrial and agricultural equipment, power tools such as drills and circular saws, as well as portable motors or machines on construction sites, on farms and in shipyards; they are suitable for use in cold storage facilities and can also be permanently installed as installation cables
01
Key Parameters
- Operating temperature
- from -50 °C to +90 °C
- Rated voltage
- 450/750 V
- Packaging
- discs, drums
02
Construction
- Veins
- Class 5 multi-strand copper wire, in accordance with the PN-EN 60228 standard, tinned upon customer request
- Insulation
- heat-resistant rubber
- Insulation Colors
- 2-wire: blue, brown 3-wire: green-yellow, blue, brown 4-wire: green-yellow, brown, black, gray 5-wire: green-yellow, blue, brown, black, gray more than 5 wires: green-yellow outer layer, remaining wires black with contrasting digital printing
- Outer coating
- orange TMPU polyurethane
03
Technical Tables
Dimension Chart
| Number and nominal cross-sectional area of conductors [n x mm²] | Approximate outer diameter of the cable [mm] | Approximate cable weight [kg/km] |
|---|---|---|
| 2 x 1 | 7,4 | 68 |
| 2 x 1,5 | 8,7 | 93 |
| 2 x 2,5 | 10,3 | 135 |
| 2 x 4 | 12,0 | 189 |
| 2 x 6 | 13,3 | 248 |
| 2 x 10 | 18,6 | 457 |
| 2 x 16 | 20,8 | 616 |
| 3 x 1 | 7,9 | 82 |
| 3 x 1,5 | 9,2 | 112 |
| 3 x 2,5 | 11,1 | 166 |
| 3 x 4 | 12,7 | 235 |
| 3 x 6 | 14,4 | 319 |
| 3 x 10 | 19,8 | 576 |
| 3 x 16 | 22,4 | 791 |
| 4 x 1 | 8,7 | 109 |
| 4 x 1,5 | 10,4 | 143 |
| 4 x 2,5 | 12,1 | 207 |
| 4 x 4 | 14,0 | 294 |
| 4 x 6 | 15,9 | 399 |
| 4 x 10 | 22,0 | 718 |
| 4 x 16 | 24,3 | 982 |
| 5 x 1 | 9,8 | 141 |
| 5 x 1,5 | 11,3 | 176 |
| 5 x 2,5 | 13,4 | 259 |
| 5 x 4 | 15,6 | 371 |
| 5 x 6 | 17,5 | 499 |
| 5 x 10 | 24,2 | 898 |
| 5 x 16 | 27,2 | 1242 |
Dimension Chart
| Number and nominal cross-sectional area of conductors [n x mm²] | Approximate outer diameter of the cable [mm] | Approximate cable weight [kg/km] |
|---|---|---|
| 7 x 1,5 | 16,1 | 350 |
| 7 x 2,5 | 18,3 | 450 |
| 10 x 1,5 | 18,2 | 430 |
| 10 x 2,5 | 21,1 | 635 |
| 12 x 1,5 | 19,1 | 455 |
| 12 x 2,5 | 22,3 | 655 |
| 14 x 1,5 | 18,6 | 550 |
| 14 x 2,5 | 25,1 | 715 |
| 18 x 1,5 | 22,4 | 660 |
| 18 x 2,5 | 26,3 | 1100 |
| 24 x 1,5 | 26,1 | 860 |
| 24 x 2,5 | 30,9 | 1650 |
Minimum bending radius
| Terms of Use | D ≤ 8 mm | 8 < D ≤ 12 mm | 12 < D ≤ 20 mm | D > 20 mm |
|---|---|---|---|---|
| ułożony na stałe | 3D | 3D | 4D | 4D |
| podłączony do urządzenia przenośnego lub ruchomego - kabel nie obciążony mechanicznie | 4D | 4D | 5D | 6D |
| przy dopuszczalnym obciążeniu mechanicznym | 6D | 6D | 6D | 8D |
D — the cable's outer diameter.