Skip to main content

MGWIRES

PRODUCT CATALOG Find a specific cable
MG WIRES / TECHNICAL DATA

LgY-K 1.5 kV

PVC-insulated power cables for rolling stock. Single-conductor cables rated for 1,500 V, intended for permanent installation in electrical systems. LgY-K 1.5 kV – Cable with a multi-strand (L), flexible (g) conductor, PVC insulation (Y), for railway rolling stock (-K), standard version.

REQUEST A QUOTE →
01

Key Parameters

Permissible long-term operating temperature
-30 °C to +65 °C
Maximum continuous operating temperature of the conductor
+70 °C
Rated voltage
1,500 V
02

Construction

Vein
Copper, multi-strand, flexible, Class 5 (per EN 60228)
Insulation
PVC, compliant with PN-88 E90115
03

Standards

STANDARD: PN-88/E-90116

04

Technical Tables

Technical Specifications Table
Nominal cross-sectional area / mm²Diameter of a single wire / (max.) / mmResistance at 20 °C / (max.) / mΩ/mInsulation wall thickness / (nom.) / mmOuter diameter of the cable / (max.) / mm
0,750,2126,0001,54,7
10,2119,5001,54,9
1,50,2613,3001,55,2
2,50,267,9801,55,6
40,314,9501,56,2
60,313,3001,57,4
100,411,9101,78,9
160,411,2101,710,4
250,410,7802,012,8
350,410,5542,013,8
500,410,3862,015,2
700,510,2722,017,4
950,510,2062,421,3
1200,510,1612,422,3